The Empire Turbine Ventilator is a dependable rotary that works automatically, continuously and silently without operating or maintenance costs. It is outside braced for strength, safety and perfect alignment. Ventilators up to and including 14” are aluminum braced. Larger sizes are steel braced for additional strength.
- Outside Braced
- Precision Built With Ball Bearings
Operation is simple and sure. When the slightest breeze touches the scientific blade construction it causes the turbine to rotate. The centrifugal force caused by the revolving turbine creates a partial vacuum within the turbine. This vacuum is then replaced by a strong upward draft of air. A powerful exhaust is thus achieved.
The lower thrust bearing is a hardened steel ball riding in a hardened steel concave seat (in sizes up to 8”) for extreme sensitivity and wearability. In larger sizes, thrust type ball bearings are used. Upper bearings on all ventilators are bronze oilless.
The rigid construction of these stormproof ventilators assures years of efficient service. No adjusting or servicing is required.
Empire Turbine Ventilators are sold through leading distributors everywhere. Available in galvanized steel, aluminum, copper or stainless steel, all which are servicable.
*sizes are measured in inches
Call for Pricing
MODEL # | METAL | SIZE* | GAUGE DECIMAL |
COPPER (OZS) | EXHAUST CAPACITY 4-MI WIND (CFM) |
APPROX. WEIGHT PACKED (lbs.) |
TV04A | Aluminum | 4 | 0.025 | 126 | 4 | |
TV04C | Copper | 4 | 16 | 126 | 7 | |
TV04G | Galvanized | 4 | 26-28 | 126 | 4.6 | |
TV04SS | Stainless Steel | 4 | 26-28 | 126 | 4.6 | |
TV05A | Aluminum | 5 | 0.025 | 136 | 5 | |
TV05C | Copper | 5 | 16 | 136 | 9 | |
TV05G | Galvanized | 5 | 26-28 | 136 | 6.4 | |
TV05SS | Stainless Steel | 5 | 26-28 | 136 | 6.4 | |
TV06A | Aluminum | 6 | 0.025 | 147 | 5 | |
TV06C | Copper | 6 | 16 | 147 | 9 | |
TV06G | Galvanized | 6 | 26-28 | 147 | 6.4 | |
TV06SS | Stainless Steel | 6 | 26-28 | 147 | 6.4 | |
TV07A | Aluminum | 7 | 0.025 | 210 | 6 | |
TV07C | Copper | 7 | 16 | 210 | 11 | |
TV07G | Galvanized | 7 | 26-28 | 210 | 7.6 | |
TV07SS | Stainless Steel | 7 | 26-28 | 210 | 7.6 | |
TV08A | Aluminum | 8 | 0.025 | 255 | 6 | |
TV08C | Copper | 8 | 16 | 255 | 11 | |
TV08G | Galvanized | 8 | 26-28 | 255 | 7.6 | |
TV08SS | Stainless Steel | 8 | 26-28 | 255 | 7.6 | |
TV09A | Aluminum | 9 | 0.025 | 357 | 8 | |
TV09C | Copper | 9 | 16 | 357 | 10 OS 1 | |
TV09G | Galvanized | 9 | 26-28 | 357 | 9.4 | |
TV09SS | Stainless Steel | 9 | 26-28 | 357 | 9.4 | |
TV10A | Aluminum | 10 | 0.025 | 425 | 8 | |
TV10C | Copper | 10 | 16 | 425 | 10 OS 1 | |
TV10G | Galvanized | 10 | 26-28 | 425 | 9.4 | |
TV10SS | Stainless Steel | 10 | 26-28 | 425 | 9.4 | |
TV12A | Aluminum | 12 | .025-.032 | 631 | 9.5 OS 1 | |
TV12C | Copper | 12 | 16 | 631 | 15 OS 2 | |
TV12G | Galvanized | 12 | 24-28 | 631 | 12.4 OS 1 | |
TV12SS | Stainless Steel | 12 | 24-28 | 631 | 12.4 OS 1 | |
TV14A | Aluminum | 14 | .025-.032 | 700 | 15 OS 2 | |
TV14C | Copper | 14 | 16 | 700 | 20 OS 2 | |
TV14G | Galvanized | 14 | 24-26 | 700 | 18.8 OS 2 | |
TV14SS | Stainless Steel | 14 | 24-26 | 700 | 18.8 OS 2 | |
TV16A | Aluminum | 16 | .025-.032 | 950 | 23 OS 2 | |
TV16C | Copper | 16 | 16 | 950 | 27 OS 2 | |
TV16G | Galvanized | 16 | 24-26 | 950 | 25.8 OS 2 | |
TV16SS | Stainless Steel | 16 | 24-26 | 950 | 25.8 OS 2 | |
TV18A | Aluminum | 18 | .025-.032 | 1200 | 29 | |
TV18C | Copper | 18 | 16-20 | 1200 | 26 | |
TV18G | Galvanized | 18 | 24-26 | 1200 | 34.4 | |
TV18SS | Stainless Steel | 18 | 24-26 | 1200 | 34.4 | |
TV20A | Aluminum | 20 | .025-.032 | 1700 | 34 | |
TV20C | Copper | 20 | 16-20 | 1700 | 38 | |
TV20G | Galvanized | 20 | 24-26 | 1700 | 37.6 | |
TV20SS | Stainless Steel | 20 | 24-26 | 1700 | 37.6 | |
TV24A | Aluminum | 24 | .025-.032 | 2350 | 45 | |
TV24C | Copper | 24 | 16-20 | 2350 | 60 | |
TV24G | Galvanized | 24 | 22-26 | 2350 | 54.6 | |
TV24SS | Stainless Steel | 24 | 22-26 | 2350 | 54.6 |
Construction Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Dimensional and Performance Data
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
12″ Turbine Ventilator Installation Instructions
SELECTING THE NUMBER OF VENTILATORS NEEDED:
To determine the number of turbine ventilators needed to properly ventilate your attic, first determine the size of your attic in square feet. Simply measure the length and width of your house, and multiply the two figures for the total square foot area. One ventilator is required for each 600 square feet of attic floor area. Note also that for satisfactory operation of these ventilators, a minimum of two square feet of louver area is required for each ventilator, around the eaves and/or exterior of the house to let outside air into the attic.
PLACEMENT OF VENTILATORS:
For optimum performance, the turbine ventilator should be installed near the peak of the roof on a rear slope with the rotating head above the peak, exposed to the wind from all directions. When installing two, place each 1/4 the distance from the end of the house. When installing three, place one in the center and the other two 1/6 the distance from each end of the house. Position of the ventilators should be free of rafters to ease installation, although this is not essential.
Installation:
- Locate adjustable base in the position(s) selected as per above instructions.
- Trace a circle on the roofing surface using the inside diameter of the adjustable base as a guide.
- Use a sharp cutting tool to remove roof shingles or material from inside circle. Remove any fasteners or shingle nails adjacent to the outside of the circle that will prevent the flange of the base from seating properly.
- Saw out the roof boards within the scribed circle.
- Loosen hardware on the adjustable base. The base is adjustable at the middle seam. Rotate the base at this point to make the top portion level when the base is seated over the roof opening. Tighten screw.
- Butter roofing cement in area around roof opening. Set the base in the roofing cement so that the top portion of the flange slides under the shingles. leaving the bottom portion of the flange over the shingles. Securely fasten the base to the roof with a minimum of eight large head roofing nails.
- Caulk all nail heads. Apply roofing cement to the shingles which extend over the flange, to the edges of any shingles which have been cut, to the high side of the base’s seam where it meets the vertical airshaft and to the exposed edge of the base mounting flange which is over the shingles.
- Fasten ventilator airshaft in a level position to the crimped collar of the base airshaft with a minimum of six sheet metal screws. Be sure the ventilator is level for proper operation.
(Spanish)
Instrucciones De Instalación De Un Ventilador Tipo Turbina De 12″
CÓmo Seleccionar el nÚmero de ventiladores que se necesitan:
Para determinar el número de ventiladores tipo turbine que se necesitan para ventilar apropiadamente su desván, primero calcule el tamaño de éste en pies cuadrados. Simplemente mida la largo y ancho de su casa, y multiplique las dos cifras para obtener el área en pies cuadrados. Se necesita un ventilador por cada 600 pies cuadrados de área de piso de desván. Observe también que para la operación satisfactoria de esto ventiladores, hace falta un mínimo de dos pies cuadrados de área de celosía alrededor de los aleros o el exterior de la casa ventilador, para dejar que entre el aire externo al desván.
Colocación de los ventiladores:
Para obtener un rendimiento óptimo del ventilador tipo turbina, se debe instalar cerca del caballete del tejado en una pendiente trasera, con el tope rotatorio sobresaliendo sobre el caballete, expuesto al viento desde todos los puntos cardinales. Cuando instale dos, coloque cada uno a 1/4 de la distancia del extremo de la casa. Cuando instale tres, cooque uno el centro y los ortos dos a 1/6 de la distancia del extremo de la casa. Los ventiladores deben instalarse donde no haya vigas, aunque esto no es esencial.
Instalación:
- Sitúe la base ajustable en el(los) lugar(es) seleccionado(s) según las instruccioines anteriores.
- Dibuje un círculo en la superficie del techo utilizando el diámetro interior de la base ajustable como guía.
- Utilice una herrmienta cortante y afilada para quitar las tablillas o material de techo del círculo interior. Quite cualquier tornillo o clavo de tablilla adyacente al exterior del círculo que pueda impedir que el reborde de la base se asient completamente.
- Corte los tablones del techo dentro del círculo marcado para hacer de paso del pozo de ventilación.
- Afloje los dispostivos de la base ajustable. La base es ajustable en la costura media. Gire la base en este punto para hacer que tope esté nivelado cuando la base est´asentada sobre la abertura del techo. Apriete el tornillo.
- Extienda el cemento de techar alredodor de la abertura en el techo. Coloque la base en el cemento de techar de modo que la parte superior del reborde se deslice bajo las tablillas, dejando la parte inferior del reborde sobre las tablillas. Asegura y fije la base al techo con un mínimo de ocho clavos de techar de cabeza grande.
- Selle todas las cabezas de clavo. Aplique cemento de techar a lastablillas que se extienden sobre el reborde, hasta los bordes de cualquier tablilla que haya sido cortada, hasta el lado alto de la costura de la base, done se encuentra con el tubo vertical de centilaciøn, y al borde expuesto del reborde de la montura de la base que está sobre las tablillas.
- Asegure el pozo de ventilación base con un mínimo de seis tornillos para chapas metálicas. Asegúrese que el ventilador quede nivelado para que funcione correctament.
French
Cosignes D’Installation Du Ventilateur À Turbine De 30 CM
Sélection Du nombre de ventilateurs nécessaires:
Pour déterminer le nombre de ventilateurs à turbine nécessaires pour aérer adéquatement votre grenier, déterminez d’abord la taille de votre grenier en pieds carrés. Il suffit de mesurer la longueur et la largeur de votre maison et de multiplier les deux chiffres pour obtenir la superficie totale en pieds carrés. Un ventilateur est nécassaire pour chaque portion de 600 pied carrés. Veuillez également prendre not que pour assurer le bon fonctionnement de ces ventilateurs, une lucarne d’au moins 2 pieds carrés est nécessaire pour chaque ventilateur, autour des avant-toits et/ou de l’extérieur de la maison pour l’air pénétrer dans grenier.
Placement des ventilateurs:
Pour un rendement optimum, le ventilateur à turbine doit être installé à proximité du sommet du toit sur une pente arriére avec la tête rotative au-dessus du sommet, de façon à l’exposer au ventilator dans toutes les directions. Lorsque vous installez duex ventilateurs, vous devez les disposer de façon à ce qu’ils soient éloignés de l’extrémité de la maison à une distance équivalente à 1/4 de la longueur totale. Lorsque vous installez trois ventilateurs, placez-en un au centre et les deux autres à une distance équivalente à 1/6 de la longueur totale. L’emplacement des ventilateurs doit être exempt de chevrons pour faciliter l’installation, bien que ce ne soit pas essentiel.
Installation:
- Placez la base réglable à la position désirée conformément aux consignes ci-dessus.
- Tracez un cercle sur la surface du toit en utilisant le diamétre intérieur de la base réglable à titre de référence.
- Utilisez un outil tranchant pour retirer les bardeaux de toit ou tout autre matériau du cercle intérieur. Retirez toutes attaches ou clous de bardeaux adjacents à l’extérieur du cercle et qui pourraient empêcher le rebord de la base d’être bien assis.
- Sciez les planches du toit à l’intérieur de cercle tracé.
- Desserrez les vis de la base réglable. La base se régle au niveau du joint central. Faire pivoter la base à cet endroit pour faire en sorte que la partie supérieure soit à niveau lorsque la base repose sur l’ouverture du toit. Serrez les vis.
- Appliquez de ciment pourr le toit autour de l’ouverture du toit. Réglez la base de façon à ce que la partie supérieure de rebord glisse sous les bareaux, laissant ainsi la partie inférieure du reborb par-dessus les bardeaux. Fixez solidement la base au toit avec au moins huit clous à grosse tête prévus à cet effet.
- Calfatez toutes les têtes de clous. Appliquez de ciment pour le toit sur les bareaux qui dépassent le rebord, sur les rebords des bardeaux qui ont été coupés, sure le côté le plus élevé du joint de la base oú il rencontre le puits d’aération et sur le rebord à découvert de la bride de fixation de la base qui se trouve au-dessus des bardeaux.
- Fixez le puits d’aéation à hauteur du collier serti du puits d’aération de la base avec au moins six vis à tôle. Assurez-vous que le ventilateur est à niveau.