Turbine Ventilators

The Empire Turbine Ventilator is a dependable rotary that works automatically, continuously and silently without operating or maintenance costs. It is outside braced for strength, safety and perfect alignment. Ventilators up to and including 14” are aluminum braced. Larger sizes are steel braced for additional strength.

  • Outside Braced
  • Precision Built With Ball Bearings

Operation is simple and sure. When the slightest breeze touches the scientific blade construction it causes the turbine to rotate. The centrifugal force caused by the revolving turbine creates a partial vacuum within the turbine. This vacuum is then replaced by a strong upward draft of air. A powerful exhaust is thus achieved.

The lower thrust bearing is a hardened steel ball riding in a hardened steel concave seat (in sizes up to 8”) for extreme sensitivity and wearability. In larger sizes, thrust type ball bearings are used. Upper bearings on all ventilators are bronze oilless.

The rigid construction of these stormproof ventilators assures years of efficient service. No adjusting or servicing is required.

Empire Turbine Ventilators are sold through leading distributors everywhere. Available in galvanized steel, aluminum, copper or stainless steel, all which are servicable.

*sizes are measured in inches

Call for Pricing

MODEL # METAL SIZE* GAUGE
DECIMAL
COPPER (OZS) EXHAUST
CAPACITY
4-MI WIND
(CFM)
APPROX.
WEIGHT
PACKED
(lbs.)
TV04A Aluminum 4 0.025 126 4
TV04C Copper 4 16 126 7
TV04G Galvanized 4 26-28 126 4.6
TV04SS Stainless Steel 4 26-28 126 4.6
TV05A Aluminum 5 0.025 136 5
TV05C Copper 5 16 136 9
TV05G Galvanized 5 26-28 136 6.4
TV05SS Stainless Steel 5 26-28 136 6.4
TV06A Aluminum 6 0.025 147 5
TV06C Copper 6 16 147 9
TV06G Galvanized 6 26-28 147 6.4
TV06SS Stainless Steel 6 26-28 147 6.4
TV07A Aluminum 7 0.025 210 6
TV07C Copper 7 16 210 11
TV07G Galvanized 7 26-28 210 7.6
TV07SS Stainless Steel 7 26-28 210 7.6
TV08A Aluminum 8 0.025 255 6
TV08C Copper 8 16 255 11
TV08G Galvanized 8 26-28 255 7.6
TV08SS Stainless Steel 8 26-28 255 7.6
TV09A Aluminum 9 0.025 357 8
TV09C Copper 9 16 357 10 OS 1
TV09G Galvanized 9 26-28 357 9.4
TV09SS Stainless Steel 9 26-28 357 9.4
TV10A Aluminum 10 0.025 425 8
TV10C Copper 10 16 425 10 OS 1
TV10G Galvanized 10 26-28 425 9.4
TV10SS Stainless Steel 10 26-28 425 9.4
TV12A Aluminum 12 .025-.032 631 9.5 OS 1
TV12C Copper 12 16 631 15 OS 2
TV12G Galvanized 12 24-28 631 12.4 OS 1
TV12SS Stainless Steel 12 24-28 631 12.4 OS 1
TV14A Aluminum 14 .025-.032 700 15 OS 2
TV14C Copper 14 16 700 20 OS 2
TV14G Galvanized 14 24-26 700 18.8 OS 2
TV14SS Stainless Steel 14 24-26 700 18.8 OS 2
TV16A Aluminum 16 .025-.032 950 23 OS 2
TV16C Copper 16 16 950 27 OS 2
TV16G Galvanized 16 24-26 950 25.8 OS 2
TV16SS Stainless Steel 16 24-26 950 25.8 OS 2
TV18A Aluminum 18 .025-.032 1200 29
TV18C Copper 18 16-20 1200 26
TV18G Galvanized 18 24-26 1200 34.4
TV18SS Stainless Steel 18 24-26 1200 34.4
TV20A Aluminum 20 .025-.032 1700 34
TV20C Copper 20 16-20 1700 38
TV20G Galvanized 20 24-26 1700 37.6
TV20SS Stainless Steel 20 24-26 1700 37.6
TV24A Aluminum 24 .025-.032 2350 45
TV24C Copper 24 16-20 2350 60
TV24G Galvanized 24 22-26 2350 54.6
TV24SS Stainless Steel 24 22-26 2350 54.6

 

 

Construction Specifications
“A” Throat Size
GAUGE
No. of Braces
Brace Material
Crown Galv.
Blade Galv.
Throat Galv.
4
24
28
26
3
Alum.
6
24
28
26
3
Alum.
8
24
28
26
3
Alum.
10
24
28
26
3
Alum.
12
24
28
24
3
Alum.
14
22
26
24
3
Alum.
16
22
26
24
3
Steel
18
22
26
24
4
Steel
20
20
26
24
4
Steel
24
20
26
22
4
Steel

 

Dimensional and Performance Data
“A” Throat Size
“B” Height
“C” Overall Width
Exhaust Capacity*
Approx. Shipping Weight
4
12
10 1/4
126
5
6
14 1/2
12 3/4
147
7
8
15
14 1/4
255
8
10
16 1/4
16 1/4
425
11
12
17
19
361
13
14
19 3/4
22 3/4
700
21
16
21 3/4
25 1/2
950
31
18
24
29
1200
38
20
25 1/4
31 5/8
1700
46
24
28 1/4
35 3/4
2350
59
*4 MPH Wind CFM

 

12″ Turbine Ventilator Installation Instructions

SELECTING THE NUMBER OF VENTILATORS NEEDED:

To determine the number of turbine ventilators needed to properly ventilate your attic, first determine the size of your attic in square feet. Simply measure the length and width of your house, and multiply the two figures for the total square foot area. One ventilator is required for each 600 square feet of attic floor area. Note also that for satisfactory operation of these ventilators, a minimum of two square feet of louver area is required for each ventilator, around the eaves and/or exterior of the house to let outside air into the attic.

PLACEMENT OF VENTILATORS:

For optimum performance, the turbine ventilator should be installed near the peak of the roof on a rear slope with the rotating head above the peak, exposed to the wind from all directions. When installing two, place each 1/4 the distance from the end of the house. When installing three, place one in the center and the other two 1/6 the distance from each end of the house. Position of the ventilators should be free of rafters to ease installation, although this is not essential.

Installation:

  1. Locate adjustable base in the position(s) selected as per above instructions.
  2. Trace a circle on the roofing surface using the inside diameter of the adjustable base as a guide.
  3. Use a sharp cutting tool to remove roof shingles or material from inside circle. Remove any fasteners or shingle nails adjacent to the outside of the circle that will prevent the flange of the base from seating properly.
  4. Saw out the roof boards within the scribed circle.
  5. Loosen hardware on the adjustable base. The base is adjustable at the middle seam. Rotate the base at this point to make the top portion level when the base is seated over the roof opening. Tighten screw.
  6. Butter roofing cement in area around roof opening. Set the base in the roofing cement so that the top portion of the flange slides under the shingles. leaving the bottom portion of the flange over the shingles. Securely fasten the base to the roof with a minimum of eight large head roofing nails.
  7. Caulk all nail heads. Apply roofing cement to the shingles which extend over the flange, to the edges of any shingles which have been cut, to the high side of the base’s seam where it meets the vertical airshaft and to the exposed edge of the base mounting flange which is over the shingles.
  8. Fasten ventilator airshaft in a level position to the crimped collar of the base airshaft with a minimum of six sheet metal screws. Be sure the ventilator is level for proper operation.

 

(Spanish)

Instrucciones De Instalación De Un Ventilador Tipo Turbina De 12″

CÓmo Seleccionar el nÚmero de ventiladores que se necesitan:

Para determinar el número de ventiladores tipo turbine que se necesitan para ventilar apropiadamente su desván, primero calcule el tamaño de éste en pies cuadrados. Simplemente mida la largo y ancho de su casa, y multiplique las dos cifras para obtener el área en pies cuadrados. Se necesita un ventilador por cada 600 pies cuadrados de área de piso de desván. Observe también que para la operación satisfactoria de esto ventiladores, hace falta un mínimo de dos pies cuadrados de área de celosía alrededor de los aleros o el exterior de la casa ventilador, para dejar que entre el aire externo al desván.

Colocación de los ventiladores:

Para obtener un rendimiento óptimo del ventilador tipo turbina, se debe instalar cerca del caballete del tejado en una pendiente trasera, con el tope rotatorio sobresaliendo sobre el caballete, expuesto al viento desde todos los puntos cardinales. Cuando instale dos, coloque cada uno a 1/4 de la distancia del extremo de la casa. Cuando instale tres, cooque uno el centro y los ortos dos a 1/6 de la distancia del extremo de la casa. Los ventiladores deben instalarse donde no haya vigas, aunque esto no es esencial.

Instalación:

 

  1. Sitúe la base ajustable en el(los) lugar(es) seleccionado(s) según las instruccioines anteriores.
  2. Dibuje un círculo en la superficie del techo utilizando el diámetro interior de la base ajustable como guía.
  3. Utilice una herrmienta cortante y afilada para quitar las tablillas o material de techo del círculo interior. Quite cualquier tornillo o clavo de tablilla adyacente al exterior del círculo que pueda impedir que el reborde de la base se asient completamente.
  4. Corte los tablones del techo dentro del círculo marcado para hacer de paso del pozo de ventilación.
  5. Afloje los dispostivos de la base ajustable. La base es ajustable en la costura media. Gire la base en este punto para hacer que tope esté nivelado cuando la base est´asentada sobre la abertura del techo. Apriete el tornillo.
  6. Extienda el cemento de techar alredodor de la abertura en el techo. Coloque la base en el cemento de techar de modo que la parte superior del reborde se deslice bajo las tablillas, dejando la parte inferior del reborde sobre las tablillas. Asegura y fije la base al techo con un mínimo de ocho clavos de techar de cabeza grande.
  7. Selle todas las cabezas de clavo. Aplique cemento de techar a lastablillas que se extienden sobre el reborde, hasta los bordes de cualquier tablilla que haya sido cortada, hasta el lado alto de la costura de la base, done se encuentra con el tubo vertical de centilaciøn, y al borde expuesto del reborde de la montura de la base que está sobre las tablillas.
  8. Asegure el pozo de ventilación base con un mínimo de seis tornillos para chapas metálicas. Asegúrese que el ventilador quede nivelado para que funcione correctament.

 

 

French

Cosignes D’Installation Du Ventilateur À Turbine De 30 CM

Sélection Du nombre de ventilateurs nécessaires:

Pour déterminer le nombre de ventilateurs à turbine nécessaires pour aérer adéquatement votre grenier, déterminez d’abord la taille de votre grenier en pieds carrés. Il suffit de mesurer la longueur et la largeur de votre maison et de multiplier les deux chiffres pour obtenir la superficie totale en pieds carrés. Un ventilateur est nécassaire pour chaque portion de 600 pied carrés. Veuillez également prendre not que pour assurer le bon fonctionnement de ces ventilateurs, une lucarne d’au moins 2 pieds carrés est nécessaire pour chaque ventilateur, autour des avant-toits et/ou de l’extérieur de la maison pour l’air pénétrer dans grenier.

Placement des ventilateurs:

Pour un rendement optimum, le ventilateur à turbine doit être installé à proximité du sommet du toit sur une pente arriére avec la tête rotative au-dessus du sommet, de façon à l’exposer au ventilator dans toutes les directions. Lorsque vous installez duex ventilateurs, vous devez les disposer de façon à ce qu’ils soient éloignés de l’extrémité de la maison à une distance équivalente à 1/4 de la longueur totale. Lorsque vous installez trois ventilateurs, placez-en un au centre et les deux autres à une distance équivalente à 1/6 de la longueur totale. L’emplacement des ventilateurs doit être exempt de chevrons pour faciliter l’installation, bien que ce ne soit pas essentiel.

Installation:

 

  1. Placez la base réglable à la position désirée conformément aux consignes ci-dessus.
  2. Tracez un cercle sur la surface du toit en utilisant le diamétre intérieur de la base réglable à titre de référence.
  3. Utilisez un outil tranchant pour retirer les bardeaux de toit ou tout autre matériau du cercle intérieur. Retirez toutes attaches ou clous de bardeaux adjacents à l’extérieur du cercle et qui pourraient empêcher le rebord de la base d’être bien assis.
  4. Sciez les planches du toit à l’intérieur de cercle tracé.
  5. Desserrez les vis de la base réglable. La base se régle au niveau du joint central. Faire pivoter la base à cet endroit pour faire en sorte que la partie supérieure soit à niveau lorsque la base repose sur l’ouverture du toit. Serrez les vis.
  6. Appliquez de ciment pourr le toit autour de l’ouverture du toit. Réglez la base de façon à ce que la partie supérieure de rebord glisse sous les bareaux, laissant ainsi la partie inférieure du reborb par-dessus les bardeaux. Fixez solidement la base au toit avec au moins huit clous à grosse tête prévus à cet effet.
  7. Calfatez toutes les têtes de clous. Appliquez de ciment pour le toit sur les bareaux qui dépassent le rebord, sur les rebords des bardeaux qui ont été coupés, sure le côté le plus élevé du joint de la base oú il rencontre le puits d’aération et sur le rebord à découvert de la bride de fixation de la base qui se trouve au-dessus des bardeaux.
  8. Fixez le puits d’aéation à hauteur du collier serti du puits d’aération de la base avec au moins six vis à tôle. Assurez-vous que le ventilateur est à niveau.